IMPLANTATION OF WATCHMAN DEVICE TO CLOSE LEFT ATRIAL APPENDAGE USING LEFT FEMORAL VEIN APPROACH

Authors

  • Naseer Ahmed
  • Giulio Molon
  • Guido Canali
  • Patrizio Mazzone
  • Laura Lanzoni
  • Alessio Rungatscher
  • Enrico Barbieri
  • Giuseppe Faggian

DOI:

https://doi.org/10.47144/phj.v51i1.1420

Abstract

An 83 years old patient with permanent Atrial Fibrillation (AF) and bleedingdisorders was referred for Left Atrial Appendage (LAA) closure. The LAAclosure device was successfully implanted using the left femoral vein approachas the right femoral vein was occluded. The trans septal puncture andimplantation of the LAA closure device were guided by fluoroscopic andtransesophageal echocardiographic images. There were no complications.Trans septal puncture guided by a combination of fluoroscopic andtransesophageal echocardiographic imaging can be safely carried out using theleft femoral vein approach as an alternative option when the right femoral vein isnot accessible.

Downloads

Download data is not yet available.

Downloads

How to Cite

1.
Ahmed N, Molon G, Canali G, Mazzone P, Lanzoni L, Rungatscher A, Barbieri E, Faggian G. IMPLANTATION OF WATCHMAN DEVICE TO CLOSE LEFT ATRIAL APPENDAGE USING LEFT FEMORAL VEIN APPROACH. Pak Heart J [Internet]. 2018Jun.5 [cited 2024Dec.24];51(1). Available from: https://pakheartjournal.com/index.php/pk/article/view/1420